NEOVEIL™ TUBE

NEOVEIL is an absorbable reinforcement material made of PGA (polyglycolic acid). It is used to reinforce soft tissue and to prevent air or fluid leakage.

Features

NEOVEIL can be in areas of the body that do not take a long time to heal. Once it is in the body, it degrades via hydrolysis and is fully absorbed approximately 15 weeks after surgery.

NEOVEIL TUBE is designed to fit surgical staplers. It enables the surgeon to cut, staple, and reinforce the resected region.

Distributors

Bio Distribution Sàrl (Netherlands, Belgium, Luxembourg)
11-13 Boulevard Grande-Duchesse Charlotte
L-1331 Luxembourg
Telephone: +352 26 25 87 31
E-Mail: biodistribution@biodistribution.lu

Europrisme Medical Groupe (France, Switzerland)
2 rue Rempart Monseigneur Freppel
Obernai, France
Telephone: +33 (0)3 88 21 19 21
Website: https://europrisme-medical.com/
E-Mail: contact@europrisme-medical.com

Europrisme Medical Groupe (Germany, Austria)
Website: https://europrisme-medical.com/
E-Mail: contact@europrisme-medical.com
   In partnership with MedXpert GmbH
   Max-Immelmann-Allee 19
   79427 Eschbach, Germany
   Telephone: +49 (0) 7634 508 563 0
   Website: https://medxpert.de
   E-Mail: info@medxpert.de

EmbioMedikal (Turkey, Northern Cyprus)
Yali Mah. 196 Sk. No:3 D:2
Guzelbahce / IZMIR
Turkey
Telephone: +90 232 264 00 75
Website: https://embiomedikal.com/
E-Mail: info@embiomedikal.com

BVM Medical Limited (United Kingdom)
BVM House
Trinity Lane, Hinckley, Leicestershire, LE10 0BL
United Kingdom
Telephone: +44 7802 160942
Website: https://www.bvmmedical.com/
E-Mail: info@bvmmedical.com

Chirurmedica S.r.l (Italy,Republic of San Marino)
Via Bardet, 33/39
65126 – Pescara (PE)
Italy
Telephone: +39 085 4510466
Website: https://www.chirurmedica.it
E-Mail: info@chirurmedica.it

MBA SURGICAL EMPOWERMENT (Spain, Portugal)
Avda. Jardín Botánico 1345, Silos del Intra
33203 Gijón, Asturias Spain
Telephone: +34 985 195 505
Website: https://www.mba.eu/en/
E-Mail: info@mba.eu

Kikgel Sp. z o.o. (Poland)
ul. M. Curie-Skłodowskiej 7
97-225 Ujazd
Poland
Telephone: +48 44 719 23 40
Website: https://kikgel.com.pl/en/
E-Mail: biuro@kikgel.com.pl

Synergy Health Care S.A. (Greece)
Aristotelous 14, PC 153 44
Gerakas, Athens, Attica
Greece
Telephone: +30 2106127832
E-Mail: info@synergyhealthcare.eu

Enterprise Medical Equipment Ltd (Israel)
15 Kinererest St, Bni Brak
Israel
Telephone: +972-3-5759463
Website: https://enterprise-surgical.com/
E-Mail: info567@enterprise-surgical.com

Download

References

Gastrointestinal:

  • Sakakura C, Ozamoto Y, Togawa T, Hagiwara A, Otsuji E, et al. A Novel Bioabsorbable Sleeve for Staple Line Reinforcement in Laparoscopic Sleeve Gastrectomy (LSG) For Morbid Obesity: Possible Usefulness for the Future Application in Operations for Alimentary Tract Cancers. JSM Clin Oncol Res. 2013 ; 1(1): 1003.
  • Naito M, Yamanashi T, Nakamura T, Miura H, Tsutsui A, Sato T, Watanabe M. Safety and efficacy of a novel linear staple device with bioabsorbable polyglicolic acid felt in laparoscopic colorectal surgery. Asian Journal of Endoscopic Surgery. 2017; 10(1): 35-39
  • Naito M, Sato T, Nakamura T, Yamanashi T, Miura H, Tsutsui A, Watanabe M. Secure overlap stapling using a linear stapler with bioabsorbable polyglycolic acid felt. Asia Journal of Endoscopic Surgery. 2017; 10(3): 308-312
  • Kimura M, Terashita Y. Use of bioabsorbable staple reinforcement material in side-to-side anastomoses: Suture line reinforcement of the weak point of the anastomosis. Ann Med Surg (Lond). 2016 ; 6: 50–55
  • Kimura M, Kuwabara Y, Taniwaki S, Mitsui A, Shibata Y, Ueno S. Improving the side-to-side stapled anastomosis: comparison of staplers for robust crotch formation . Surgery for Obesity and Related Diseases. 2018; 14(1): 16-21
  • Naito M, Miura H, Nakamura T, Sato T, Yamanashi T, Tsutsui A, Watanabe M. Sutureless functional end-to-end anastomosis using a linear stapler with polyglycolic acid felt for intestinal anastomoses. Ann Med Surg (Lond). 2017; 17: 50–53a
  • Nagahisa Y, Morikawa A, Kato T, Hashida K, Ome Y, Kawamoto K. Feasibility of Endo GIA™ Reinforced Reload with Tri-Staple™ Technology for delta-shaped anastomosis. Asian Journal of Surgery. 2018; 41(5): 448-453

Pancreas:

  • Kawai M, et al. Reinforced staplers for distal pancreatectomy. Langenbecks Arch Surgery. 2017; 402: 1197-1204
  • Hayashibe A, Ogino N. Clinical study for pancreatic fistula after distal pancreatectomy with mesh reinforcement. Asian Journal of Surgery. 2018; 41: 236-240

Lung:

  • Shigeeda W, Deguchi H, Tomoyasu M, Kaneko Y, Kanno H, Tanita T, Saito H. The utility of the Stapler with PGA sheet for pulmonary wedge resection: a propensity score-matched analysis. Journal of Thoracic Disease. 2019; 11(4): 1546-1553