NEOVEIL™ TUBE

NEOVEIL is an absorbable reinforcement material made of PGA (polyglycolic acid). It is used to reinforce soft tissue and to prevent air or fluid leakage.

Features

NEOVEIL can be in areas of the body that do not take a long time to heal. Once it is in the body, it degrades via hydrolysis and is fully absorbed approximately 15 weeks after surgery.

NEOVEIL TUBE is designed to fit surgical staplers. It enables the surgeon to cut, staple, and reinforce the resected region.

Download

References

Gastrointestinal:

  • Sakakura C, Ozamoto Y, Togawa T, Hagiwara A, Otsuji E, et al. A Novel Bioabsorbable Sleeve for Staple Line Reinforcement in Laparoscopic Sleeve Gastrectomy (LSG) For Morbid Obesity: Possible Usefulness for the Future Application in Operations for Alimentary Tract Cancers. JSM Clin Oncol Res. 2013 ; 1(1): 1003.
  • Naito M, Yamanashi T, Nakamura T, Miura H, Tsutsui A, Sato T, Watanabe M. Safety and efficacy of a novel linear staple device with bioabsorbable polyglicolic acid felt in laparoscopic colorectal surgery. Asian Journal of Endoscopic Surgery. 2017; 10(1): 35-39
  • Naito M, Sato T, Nakamura T, Yamanashi T, Miura H, Tsutsui A, Watanabe M. Secure overlap stapling using a linear stapler with bioabsorbable polyglycolic acid felt. Asia Journal of Endoscopic Surgery. 2017; 10(3): 308-312
  • Kimura M, Terashita Y. Use of bioabsorbable staple reinforcement material in side-to-side anastomoses: Suture line reinforcement of the weak point of the anastomosis. Ann Med Surg (Lond). 2016 ; 6: 50–55
  • Kimura M, Kuwabara Y, Taniwaki S, Mitsui A, Shibata Y, Ueno S. Improving the side-to-side stapled anastomosis: comparison of staplers for robust crotch formation . Surgery for Obesity and Related Diseases. 2018; 14(1): 16-21
  • Naito M, Miura H, Nakamura T, Sato T, Yamanashi T, Tsutsui A, Watanabe M. Sutureless functional end-to-end anastomosis using a linear stapler with polyglycolic acid felt for intestinal anastomoses. Ann Med Surg (Lond). 2017; 17: 50–53a
  • Nagahisa Y, Morikawa A, Kato T, Hashida K, Ome Y, Kawamoto K. Feasibility of Endo GIA™ Reinforced Reload with Tri-Staple™ Technology for delta-shaped anastomosis. Asian Journal of Surgery. 2018; 41(5): 448-453

Pancreas:

  • Kawai M, et al. Reinforced staplers for distal pancreatectomy. Langenbecks Arch Surgery. 2017; 402: 1197-1204
  • Hayashibe A, Ogino N. Clinical study for pancreatic fistula after distal pancreatectomy with mesh reinforcement. Asian Journal of Surgery. 2018; 41: 236-240

Lung:

  • Shigeeda W, Deguchi H, Tomoyasu M, Kaneko Y, Kanno H, Tanita T, Saito H. The utility of the Stapler with PGA sheet for pulmonary wedge resection: a propensity score-matched analysis. Journal of Thoracic Disease. 2019; 11(4): 1546-1553